← Todas as FerramentasQueda de Tensão
Estime a queda de tensão num circuito.
Electricity isn't perfectly efficient; as current travels through a wire, it meets resistance, causing some of the energy to be lost as heat. This loss results in a 'Voltage Drop' at the far end of the cable. For long wire runs—like powering a detached garage or a backyard shed—this drop can be significant, causing motors to burn out or lights to flicker. Our Voltage Drop Calculator helps you determine if your chosen wire gauge (AWG) is sufficient for the distance and current load of your project, ensuring your electrical installation is both safe and code-compliant.
Como funciona
This tool uses the standard resistance values for American Wire Gauge (AWG) copper conductors. It calculates the total resistance of the one-way distance (multiplied by 2 for the complete circuit) and applies Ohm's Law (V = I × R) to find the voltage lost across that resistance.
Fórmula de cálculo
V_drop = I × R_total
Exemplos de cálculo
1. **Long Run**: 120V, 15A, 100ft on 14 AWG = **~7.5V loss (6.3%)**.
Por que usar essa ferramenta no seu dia a dia?
Segurança elétrica de nível profissional. Este serviço é uma verificação vital para qualquer pessoa que forneça energia a edifícios isolados ou equipamentos externos, ajudando você a escolher os materiais certos para evitar riscos de incêndio e danos ao equipamento.
Dica
Salve esta ferramenta nos favoritos para acesso rápido. Tudo funciona localmente no seu navegador.